STRUCTURE
  • RCC FRAME WITH RC FOUNDATIONS AND ANTI-TERMITE TREATMENT CONFIRMING TO ISS.
  • OUTER WALLS: 9" THICK, BRICK OR 200 MM THICK BLOCK WORK.
  • INTERNAL PARTITION WALLS: 4 ˝ “THICK, BRICK OR 100 MM THICK BLOCK WORK.
  • CEILING HEIGHT: 9'-4" CLEAR FROM SLAB BOTTOM EXCEPT BELOW TOILETS.
CEILING
  • LIVING, DINING & BEDROOMS: CEMENT PLASTER & WALL PUTTY (JK OR EQUIVALENT) AND OBD PAINT.
  • TOILETS, KITCHEN & BALCONY: CEMENT PLASTER AND CEMENT PAINT.
WALL FINISHES
  • INTERNAL WALLS: CEMENT PLASTER AND WALL PUTTY (JK OR EQUIVALENT) AND OBD PAINT.
  • TOILET WALLS: GLAZED CERAMIC TILES UPTO 7 FEET HEIGHT (COLOUR AND SIZE AS RECOMMENDED BY THE ARCHITECT).
  • BALCONIES AND OTHER AREAS: CEMENT PLASTER AND CEMENT PAINT.
  • WASH AREAS: CERAMIC TILES.
  • KITCHENS: GLAZED CERAMIC TILES UPTO 2' ABOVE THE KITCHEN PLATFORM.
  • EXTERIORS: CEMENT PLASTER AND EXTERIOR PAINT - ASIAN PAINTS (APEX OR EQUIVALENT).
FLOOR FINISHES
  • LIVING & DINING: MARBLE SLABS.
  • BEDROOMS: GRANAMITE TILES.
  • KITCHEN, UTILITY: BALCONIES & TOILETS: CERAMIC TILES WITH 3" HIGH SKIRTING WHEREVER POSSIBLE.
COMMON AREA FINISHES
  • STAIRCASE & LOBBIES: MARBLE STONE/KOTA STONE.
  • STAIRCASE WALLS: CEMENT PLASTER AND ENAMEL PAINT UPTO 5 FEET HEIGHT.
  • STILT CAR PARKS: GRANOLITHIC FLOORING.
  • DRIVEWAYS: CEMENT TILES PAVER BLOCK.
DOORS & WINDOWS
  • ENTRANCE DOORS: TEAKWOOD FRAME & 35 MM THICK, MELAMINE POLISHED, MASONITE CRAFTMASTER SHUTTER WITH GODREJ ULTRA LOCK OR EQUIVALENT.
  • BED ROOMS: CHEMICALLY TREATED KILN SEASONED SALWOOD FRAME & 32MM THICK TEAK FACED FLUSH SHUTTER WITH GODREJ CYLINDRICAL LOCKS OR EQUIVALENT. FRNECH POLISH ON BOTH SIDES. FOR WINDOWS: SALWOOD FRAME & TEAKWOOD GLAZED SHUTTER PAINTED.
TOILET DOORS
  • 30 MM THICK FRP DOORS WITH GODREJ CYLINDRICAL LATCH.
TOILETS
  • PARRYWARE/EQUIVALENT MAKE-OFF-WHITE AND/OR WHITE COLOR.
  • FLOOR MOUNTED EWCS.
  • SOLID SURFACE CASTLITH/PORCELAN WASH BASINS.
  • CP FITTINGS OF 'JAQUAR' CONTINENTAL RANGE OR EQUIVALENT MAKE.
  • WALL MIXER WITH OVERHEAD SHOWER.
  • PROVISION FOR GEYSER, EXHAUST FAN, AND OTHER APPLIANCES.
ELECTRICAL
  • CONCEALED INSULATED COPPER MULTI-STRAND WIRES.
  • MCB REQUIPPED DISTRIBUTION BOARD.
  • SWITCHES & SOCKETS-ANCHOR/EQUIVALENT.
POWER SUPPLY & GENERATOR
  • 3 PHASE POWER SUPPLY WITH GENERATOR BACK UP FOR APARTMENT (LIGHTS, FANS, 5A ETC.), COMMON AREAS, LIFTS AND PUMPS.
WATER
  • ADEQUATE BOREWELLS.
  • PROVISION OF RO PLANT.
  • UNDERGROUND RCC SUMP.
  • OVERHEAD TANK WITH PARTITION DRINKING/BOREWELL WATER.
SEWERAGE
  • SEWERAGE TREATMENT PLANT.
  • THE WATER WILL BE SAFELY RECYCLED FOR WATERING THE GARDENS ETC.
LIFT
  • ONE SIX PASSENGER LIFT AND ONE BED LIFT WITH AUTOMATIC DOORS, FOR EACH APARTMENT BLOCK.
LANDSCAPPING
  • IN OPEN AREAS TO THE MAXIMUM POSSIBLE EXTENT.
  • IN CAR PARKING AREAS AND DRIVEWAYS.
CAR PARKING
  • COVERED CAR PARKING (LIMITED NUMBERS) IS PROVIDED IN THE STILT FLOOR AND OPEN CAR PARKING ALONG THE PERIPHERY.